{"id":3246,"date":"2024-06-05T14:31:20","date_gmt":"2024-06-05T12:31:20","guid":{"rendered":"https:\/\/www.cfos-emobility.de\/network\/antworten\/modbus-com-fehler\/"},"modified":"2024-06-06T07:48:11","modified_gmt":"2024-06-06T05:48:11","slug":"modbus-com-fehler","status":"publish","type":"cma_thread","link":"https:\/\/www.cfos-emobility.de\/network\/antworten\/modbus-com-fehler\/","title":{"rendered":"Modbus, COM Fehler"},"content":{"rendered":"<p>Hallo,<\/p>\n<p>ich wei\u00df gar nicht, wo ich anfangen soll.<\/p>\n<p>Ich habe im Verbund 6x cFos Wallbox, die h\u00e4ngen paarweise an einem Halter zwischen den Parkpl\u00e4tzen. Die DTS353 Z\u00e4hler h\u00e4ngen im Verteilerschrank. Das Modbus-Kabel l\u00e4uft also: Z\u00e4hler1 &#8211; WB1 &#8211; WB2\u00a0 &#8211; Z\u00e4hler2 &#8211; Z\u00e4hler3 &#8211; WB3 &#8211; WB4 &#8211; Z\u00e4hler4 &#8211; Z\u00e4hler5 &#8211; WB5 &#8211; WB6 &#8211; Z\u00e4hler6<\/p>\n<p>Seit geraumer Zeit haben alle (bis auf einer) COM Fehler. Die Z\u00e4hler sind aber erreichbar. Ich kann z.B. die Z\u00e4hler aus den WBen abh\u00e4ngen und sie werden dann alle von jeder WB erkannt. Ich kann auch von WB1 an Z\u00e4hler6 Modbus Befehle senden (Werte schreiben, z.B. ID \u00e4ndern) und die Werte auslesen, geht alles. Aber die eingebundenen Z\u00e4hler zeigen permanent COM Fehler und es werden auch keine Z\u00e4hlerst\u00e4nde ausgegeben (bis auf einer).<\/p>\n<p>Ich habe schon die Config gesichert und neu begonnen zu konfigurieren, leider das Gleiche.<\/p>\n<p>Hat jemand einen TIP??<\/p>\n<p>Gru\u00df, Volker<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hallo, ich wei\u00df gar nicht, wo ich anfangen soll. Ich habe im Verbund 6x cFos Wallbox, die h\u00e4ngen paarweise an einem Halter zwischen den Parkpl\u00e4tzen. Die DTS353 Z\u00e4hler h\u00e4ngen im Verteilerschrank. Das Modbus-Kabel l\u00e4uft also: Z\u00e4hler1 &#8211; WB1 &#8211; WB2\u00a0 &#8211; Z\u00e4hler2 &#8211; Z\u00e4hler3 &#8211; WB3 &#8211; WB4 &#8211; Z\u00e4hler4 &#8211; Z\u00e4hler5 &#8211; WB5 &#8211; [&hellip;]<\/p>\n","protected":false},"author":63,"featured_media":0,"template":"","tags":[],"cma_category":[],"cma_difficulty_level":[],"class_list":["post-3246","cma_thread","type-cma_thread","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Modbus, COM Fehler - cFos eMobility Network<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.cfos-emobility.de\/network\/antworten\/modbus-com-fehler\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Modbus, COM Fehler - cFos eMobility Network\" \/>\n<meta property=\"og:description\" content=\"Hallo, ich wei\u00df gar nicht, wo ich anfangen soll. Ich habe im Verbund 6x cFos Wallbox, die h\u00e4ngen paarweise an einem Halter zwischen den Parkpl\u00e4tzen. Die DTS353 Z\u00e4hler h\u00e4ngen im Verteilerschrank. Das Modbus-Kabel l\u00e4uft also: Z\u00e4hler1 &#8211; WB1 &#8211; WB2\u00a0 &#8211; Z\u00e4hler2 &#8211; Z\u00e4hler3 &#8211; WB3 &#8211; WB4 &#8211; Z\u00e4hler4 &#8211; Z\u00e4hler5 &#8211; WB5 &#8211; [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.cfos-emobility.de\/network\/antworten\/modbus-com-fehler\/\" \/>\n<meta property=\"og:site_name\" content=\"cFos eMobility Network\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-06T05:48:11+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@cFosEmobility\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"1\u00a0Minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/antworten\\\/modbus-com-fehler\\\/\",\"url\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/antworten\\\/modbus-com-fehler\\\/\",\"name\":\"Modbus, COM Fehler - cFos eMobility Network\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/#website\"},\"datePublished\":\"2024-06-05T12:31:20+00:00\",\"dateModified\":\"2024-06-06T05:48:11+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/antworten\\\/modbus-com-fehler\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/antworten\\\/modbus-com-fehler\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/antworten\\\/modbus-com-fehler\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fragen\",\"item\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/antworten\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Modbus, COM Fehler\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/#website\",\"url\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/\",\"name\":\"cFos eMobility Network\",\"description\":\"Das cFos Power Brain Community Portal\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/#organization\",\"name\":\"cFos eMobility GmbH\",\"url\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/cfos-emobility-logo.jpg\",\"contentUrl\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/cfos-emobility-logo.jpg\",\"width\":221,\"height\":80,\"caption\":\"cFos eMobility GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.cfos-emobility.de\\\/network\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/cFosEmobility\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Modbus, COM Fehler - cFos eMobility Network","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.cfos-emobility.de\/network\/antworten\/modbus-com-fehler\/","og_locale":"de_DE","og_type":"article","og_title":"Modbus, COM Fehler - cFos eMobility Network","og_description":"Hallo, ich wei\u00df gar nicht, wo ich anfangen soll. Ich habe im Verbund 6x cFos Wallbox, die h\u00e4ngen paarweise an einem Halter zwischen den Parkpl\u00e4tzen. Die DTS353 Z\u00e4hler h\u00e4ngen im Verteilerschrank. Das Modbus-Kabel l\u00e4uft also: Z\u00e4hler1 &#8211; WB1 &#8211; WB2\u00a0 &#8211; Z\u00e4hler2 &#8211; Z\u00e4hler3 &#8211; WB3 &#8211; WB4 &#8211; Z\u00e4hler4 &#8211; Z\u00e4hler5 &#8211; WB5 &#8211; [&hellip;]","og_url":"https:\/\/www.cfos-emobility.de\/network\/antworten\/modbus-com-fehler\/","og_site_name":"cFos eMobility Network","article_modified_time":"2024-06-06T05:48:11+00:00","twitter_card":"summary_large_image","twitter_site":"@cFosEmobility","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"1\u00a0Minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.cfos-emobility.de\/network\/antworten\/modbus-com-fehler\/","url":"https:\/\/www.cfos-emobility.de\/network\/antworten\/modbus-com-fehler\/","name":"Modbus, COM Fehler - cFos eMobility Network","isPartOf":{"@id":"https:\/\/www.cfos-emobility.de\/network\/#website"},"datePublished":"2024-06-05T12:31:20+00:00","dateModified":"2024-06-06T05:48:11+00:00","breadcrumb":{"@id":"https:\/\/www.cfos-emobility.de\/network\/antworten\/modbus-com-fehler\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.cfos-emobility.de\/network\/antworten\/modbus-com-fehler\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.cfos-emobility.de\/network\/antworten\/modbus-com-fehler\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.cfos-emobility.de\/network\/"},{"@type":"ListItem","position":2,"name":"Fragen","item":"https:\/\/www.cfos-emobility.de\/network\/antworten\/"},{"@type":"ListItem","position":3,"name":"Modbus, COM Fehler"}]},{"@type":"WebSite","@id":"https:\/\/www.cfos-emobility.de\/network\/#website","url":"https:\/\/www.cfos-emobility.de\/network\/","name":"cFos eMobility Network","description":"Das cFos Power Brain Community Portal","publisher":{"@id":"https:\/\/www.cfos-emobility.de\/network\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.cfos-emobility.de\/network\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.cfos-emobility.de\/network\/#organization","name":"cFos eMobility GmbH","url":"https:\/\/www.cfos-emobility.de\/network\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.cfos-emobility.de\/network\/#\/schema\/logo\/image\/","url":"https:\/\/www.cfos-emobility.de\/network\/wp-content\/uploads\/2021\/12\/cfos-emobility-logo.jpg","contentUrl":"https:\/\/www.cfos-emobility.de\/network\/wp-content\/uploads\/2021\/12\/cfos-emobility-logo.jpg","width":221,"height":80,"caption":"cFos eMobility GmbH"},"image":{"@id":"https:\/\/www.cfos-emobility.de\/network\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/cFosEmobility"]}]}},"_links":{"self":[{"href":"https:\/\/www.cfos-emobility.de\/network\/wp-json\/wp\/v2\/cma_thread\/3246","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cfos-emobility.de\/network\/wp-json\/wp\/v2\/cma_thread"}],"about":[{"href":"https:\/\/www.cfos-emobility.de\/network\/wp-json\/wp\/v2\/types\/cma_thread"}],"author":[{"embeddable":true,"href":"https:\/\/www.cfos-emobility.de\/network\/wp-json\/wp\/v2\/users\/63"}],"wp:attachment":[{"href":"https:\/\/www.cfos-emobility.de\/network\/wp-json\/wp\/v2\/media?parent=3246"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cfos-emobility.de\/network\/wp-json\/wp\/v2\/tags?post=3246"},{"taxonomy":"cma_category","embeddable":true,"href":"https:\/\/www.cfos-emobility.de\/network\/wp-json\/wp\/v2\/cma_category?post=3246"},{"taxonomy":"cma_difficulty_level","embeddable":true,"href":"https:\/\/www.cfos-emobility.de\/network\/wp-json\/wp\/v2\/cma_difficulty_level?post=3246"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}