    "rtype": 2, // 0 = modbus, 1 = http/json, 2 = mqtt
    "mtype": 4, // 0 = other, 1 = meter, 2 = inverter, 4 = battery
    
    "name": "Marstek Venus (Lilygo RS485 MQTT)",
    "manufacturer": "Marstek",
    "dev_type": "marstek_lilygors485_mqtt",

    "delay_accumulated": true,

    "type_designation": {
        "address": "",
        "type": "string",
        "fixed": "Battery"
    },
    "version": {
        "address": "",
        "type": "string",
        "fixed": "0.1"
    },
    "firmware_version": {
        "address": "marstek/sensor/marstek_firmware_version/state",
        "type": "string",
        "regex": ".*"
    },
    "serial": {
        "address": "marstek/sensor/marstek_device_name/state",
        "type": "string",
        "regex": ".*"
    },

    "power_w": {
        "address": "marstek/sensor/marstek_ac_power/state",
        "type": "int16",
        "regex": ".*",
        "resolution": -1
    },

    "soc": {
        "address": "marstek/sensor/marstek_battery_state_of_charge/state",
        "type": "float",
        "regex": ".*"
    },

    "import_wh": {
        "address": "marstek/sensor/marstek_total_charging_energy/state",
        "type": "float",
        "regex": ".*",
        "resolution": 1000
    },
    "export_wh": {
        "address": "marstek/sensor/marstek_total_discharging_energy/state",
        "type": "float",
        "regex": ".*",
        "resolution": 1000
    },
 
    "*Remaining Energy (kWh)": {
        "address": "marstek/sensor/marstek_battery_remaining_capacity/state",
        "type": "float",
        "regex": ".*"
    },
    "*Internal Temperature (°C)": {
        "address": "marstek/sensor/marstek_internal_temperature/state",
        "type": "float",
        "regex": ".*"
    },
    "*Work Mode": {
        "address": "marstek/select/marstek_user_work_mode/state",
        "type": "string",
        "regex": ".*"
    },

    "outputs": [
       {
           "address": "POST http://lilygo-rs485/number/marstek_forcible_charge_power/set?value=${charge_power_w}"
       },
       {
           "address": "POST http://lilygo-rs485/number/marstek_forcible_discharge_power/set?value=${discharge_power_w}"
       },
       {
           "address": "POST http://lilygo-rs485/select/marstek_forcible_charge_discharge/set?option=${if charge_power_w > 0`charge`discharge}"
       }
    //    {
    //         "address": "POST http://lilygo-rs485/select/marstek_user_work_mode/set?option=${if _num_charging > 0`manual`anti-feed}"
    //    }
    ]
 }
 